Release Notes 2020-01-13

Version Information

OpenEdge Release

Version Information

11.3.3, 11.3.4, 11.4, 11.6.2, 11.6.3, 11.7, 11.7.1, 11.7.2, 11.7.3.007, 11.7.4, 11.7.5, 12.0, 12.1

Release 11.3 #56626@2020-01-13

OpenEdge 12.1 support!

We are please to announce that we are not aware of any issues using the SmartComponent Library on OpenEdge 12.1. We hereby declare OpenEdge 12.1 fully supported for the SmartComponent Library as of the release of September 21st 2019.

OpenEdge 12.0 support!

We are please to announce that we are not aware of any issues using the SmartComponent Library on OpenEdge 12.0. We hereby declare OpenEdge 12.0 fully supported for the SmartComponent Library as of the release of May 1st 2019.

OpenEdge 11.7.4 support!

We are please to announce that we are not aware of any issues using the SmartComponent Library on OpenEdge 11.7.4. We hereby declare OpenEdge 11.7.4 fully supported for the SmartComponent Library as of the release of November 5th 2018.

OpenEdge 11.7.3 support!

The previously reported issues with the Progress Developer Studio Visual Designer (Visual Designer related OpenEdge 11.7.3 product alert!!!) has been resolved by Progress Software with Hotfix 007 of OpenEdge 11.7.3. We hereby announce full compatibility of the SmartComponent Library with OpenEdge 11.7.3.007. 

Besides the issue with the Visual Designer however, we have not been aware of any incompatibilities with OpenEdge 11.7.3. 

.NET Framework Version 4.7

.NET 4.7 is not supported with OpenEdge 11.x, see: Is .NET 4.7 certified and supported for OpenEdge? 

Progress has reported severy issues with OpenEdge GUI for .NET and .NET 4.7: GUI .Net Application crashes after .Net upgrade to 4.7

When using the .NET Framework 4.7, please make sure, you upgrade to OpenEdge 11.6.4 or OpenEdge 11.7.2 or later. Also, it may be required to recompile the application on a PC running .NET Framework 4.7 when applications are also executed on a PC with .NET Framework 4.7.

Introducing the SmartComponent Library developer forum

Got questions about using the SmartComponent Library? Wish to discuss feature requests with other users of the SmartComponent Library? To facilitate networking in the growing number of SmartComponent Library users and developers, we've added a developer forum on our new home-page. The developer forum can be found at: https://www.consultingwerk.com/support/forum 

A login is required to participate in the forum. Don't be shy - create your account today!

Announcing the SmartFramework ERD Designer

We are announcing the availability of the SmartFramework ERD Designer

Release Notes

Following the release of the OpenEdge 11.7 Release we have completed our testing of the SmartComponent Library on this release of Progress and are proud to announce formal support for the SmartComponent Library on OpenEdge 11.7 with the 2017-04-24 release of the SmartComponent Library. Generally we recommend customers on OpenEdge 11 to upgrade to OpenEdge 11.7 quickly. Starting the 2017-07-14 release we are supporting OpenEdge 11.7 Service Pack 1 (11.7.1).

Starting the 2015-10-09 release the Business Entity Designer will feature a start page with links to most recent release note articles on this site.

With SCL-751 we have adopted native Enums for OpenEdge 11.6. To activate this feature customers must add a definition to products.i. SCL-751 provides details for this.

With SCL-1113 we have modified the templates for SmartWindowForms and SmartTabFolderPages generated from the Business Entity Designer. We have removed the initialization of the viewer controls SmartTableIOState property (value was set to "NoDataSource" within the InitializeComponent method). Customers using their own set of templates should adopt the same fix to their templates.

OpenEdge 11.7.3 compatibility

During our tests on OpenEdge 11.7.3 we have experienced the following issues: 

  • [SCL-2216] - 11.7.3 Visual Designer disabling properties of ABL user controls

The issue has been resolved by Progress Software with hotfix 007 for OpenEdge 11.7.3.

OpenEdge 11.7.2 compatibility

During our tests on OpenEdge 11.7.2 we have experienced two issues: 

  • [SCL-2007] - Correct support for WebHandler in CcsServiceManager
  • [SCL-2008] - Closing SmartWindowForm causes crash on OpenEdge 11.7.2

We consider it mandatory for customers using OpenEdge 11.7.2 to use at least the release #44166@2017-11-27 of the SmartComponent Library. 

Due to an fix for

  • [SCL-1924] - SmartViewerControl: copy mechanism cannot cope with clob datatype

from Progress Software for in OpenEdge 11.7.2.001 we further recommend all customers to apply this hotfix as well. 

New Versions of Proparse .NET Assemblies (30 December 2018)

We have updated proparse with further enhancements in this release (see https://github.com/consultingwerk/proparse/releases/tag/4.0.1.1177). Please download the .NET Assemblies ZIP file from our ESD and replace the proparse.net.dll in your environment with the latest one. The new assembly reference is:

<assembly name="proparse.net, Version=4.0.1.1177, Culture=neutral, PublicKeyToken=cda1b098b1034b24"/>

As proparse is used by our Business Entity Generator, this new version of the proparse.net Assembly is also relevant for customers not doing GUI for .NET development and require support for parsing new ABL language constructs.

This version of proparse provides additional debug information when errors are thrown from proparse.net.dll.

New Version of the Consultingwerk.SmartComponents Assemly (09 January 2019)

To support the new SmartFilterControl and the "Filter" link between the SmartFilterControl/SmartDynamciFilterControl and a SmartBusinessEntityAdapter or SmartDatasetChildAdapter we have updated the Consultingwerk.SmartComponents.dll. The new Assembly reference is:

<assembly name="Consultingwerk.SmartComponents, Version=2.2.0.49856, Culture=neutral, PublicKeyToken=10603cb31df311b3"/>

Customers need to update this Assembly in order to compile the latest releases of the SmartComponent Library.

Hybrid Realm now using IAuthenticationService

We've updated the SmartHybridRealm class used for http authentication to leverage the IAuthenticationService. It is therefor required that for AppServers requiring http Authentication (e.g. REST or Web) the correct IAuthenticationService implementation is registered (using service.xml files).

Customers relying on the previous behavior should ensure that the Consultingwerk.SmartFramework.Authentication.AuthenticationService is regsitered as the IAuthenticationService. This implementation will auhtenticate users against the password stored in the SmartUser database table. 

When users with no Login Company set should be able to login using the SmartHybridRealm, it's required to set the Login Company Tennant Domain (similar to the field in the Login Company Maintenance) in the .restapplicationsettings / .applicationsettings, e.g.:


 "DefaultAuthenticationDomain": "consultingwerk" 

This is required as the Hydrid Realm Interface from Progress does not provide the domain name to the authentication method. 

Web Handler overview

This is an overview of the web handlers supported by this release

defaultHandler=OpenEdge.Web.CompatibilityHandler
handler1=Consultingwerk.OERA.JsdoGenericService.WebHandler.CatalogWebHandler: /Catalog/{EntityName}
handler2=Consultingwerk.OERA.JsdoGenericService.WebHandler.CatalogsWebHandler: /Catalogs/{PackageName}
handler3=Consultingwerk.OERA.JsdoGenericService.WebHandler.CountWebHandler: /Resource/{EntityName}/count
handler4=Consultingwerk.OERA.JsdoGenericService.WebHandler.ResourceSubmitWebHandler: /Resource/{EntityName}/SubmitData
handler5=Consultingwerk.OERA.JsdoGenericService.WebHandler.InvokeMethodWebHandler: /Resource/{EntityName}/{MethodName}
handler6=Consultingwerk.OERA.JsdoGenericService.WebHandler.ResourceWebHandler: /Resource/{EntityName}
handler7=Consultingwerk.OERA.JsdoGenericService.WebHandler.BusinessServicesWebHandler: /BusinessServices/{OutputFormat}/{PackageName}
handler8=Consultingwerk.Web2.WebHandler.SmartMenuWebHandler: /SmartMenu/{MenuStructureId}
handler9=Consultingwerk.Web2.WebHandler.SmartMenuStructureWebHandler: /SmartMenuStructure
handler10=Consultingwerk.Web2.WebHandler.SmartRoutesWebHandler: /SmartRoutes
handler11=Consultingwerk.Web2.Services.SmartViewsHandler.SmartGridWebHandler: /SmartViews/Grid/{EntityName}/{ViewName}/{DetailTemplate}
handler12=Consultingwerk.Web2.Services.SmartViewsHandler.SmartGridWebHandler: /SmartViews/Grid/{EntityName}/{ViewName}
handler13=Consultingwerk.Web2.Services.SmartViewsHandler.SmartGridWebHandler: /SmartViews/Grid/{CustomViewName}
handler14=Consultingwerk.Web2.Services.SmartViewsHandler.SmartViewerWebHandler: /SmartViewer/Viewer/{EntityName}/{ViewName}
handler15=Consultingwerk.Web2.Services.SmartViewsHandler.SmartViewerWebHandler: /SmartViewer/Viewer/{ObjectName}
handler16=Consultingwerk.Web2.Services.SmartViewsHandler.SmartFormWebHandler: /SmartForm/{FormTemplate}/{EntityName}/{ViewName}
handler17=Consultingwerk.Web2.Services.SmartViewsHandler.SmartFormWebHandler: /SmartForm/{FormTemplate}/{ObjectName}
handler18=Consultingwerk.Web2.WebHandler.SmartMessageWebHandler: /SmartMessage/{MessageGroup}/{MessageNumber}
handler19=Consultingwerk.Web2.WebHandler.GetImageWebHandler: /Image/{FileName}
handler20=Consultingwerk.Web2.WebHandler.SmartValueListWebHandler: /ValueList/{ValueList}
handler21=Consultingwerk.Web2.WebHandler.SmartAttachmentsWebHandler: /Attachments/{Table}/{KeyValues}
handler22=Consultingwerk.Web2.WebHandler.SmartAttachmentWebHandler: /Attachment/{Guid}
handler23=Consultingwerk.Web2.WebHandler.SessionContextWebHandler: /SessionContext
handler24=Consultingwerk.Web2.WebHandler.ContextPropertiesWebHandler: /ContextProperties/{PropertyName}
handler25=Consultingwerk.Web2.WebHandler.ContextPropertiesWebHandler: /ContextProperties
handler26=Consultingwerk.Web2.WebHandler.SessionInfoWebHandler: /SessionInfo
handler27=Consultingwerk.Web2.WebHandler.FileSearchWebHandler: /FileSearch/{FileName}
handler28=Consultingwerk.Web2.WebHandler.ExecuteAblWebHandler: /ExecuteAbl
handler29=Consultingwerk.Web2.WebHandler.SmartLanguagesWebHandler: /Languages
handler30=Consultingwerk.OERA.RestResource.RestEntitiesWebHandler: /Entities
handler31=Consultingwerk.OERA.Swagger.SwaggerWebHandler: /Swagger/{EntityName}
handler32=Consultingwerk.OERA.Swagger.SwaggerRestEntitiesWebHandler: /SwaggerEntities/{OutputType}
handler33=Consultingwerk.Web2.WebHandler.SmartTokenSecurityCheckWebHandler: /TokenSecurityCheck/{ObjectName}
handler34=Consultingwerk.Web2.WebHandler.SmartTokenSecurityCheckWebHandler: /TokenSecurityCheck
handler35=Consultingwerk.Web2.WebHandler.SmartEntityTableMappingHandler: /EntityTableMapping/{EntityName}/{TableName}/{UiTypeCodes}
handler36=Consultingwerk.Web2.WebHandler.SmartTreeRootNodeWebHandler: /SmartViews/TreeRootNode/{rootnodeid}
handler37=Consultingwerk.Web2.WebHandler.SmartTreeChildNodesWebHandler: /SmartViews/TreeChildNodes/{parentnodeid}
handler38=Consultingwerk.Web2.WebHandler.SmartSecurityCheckWebHandler: /IsRestricted/{SecurityRealmCode}/{SecurityItemGuid}
handler39=Consultingwerk.Web2.WebHandler.SmartFieldSecurityCheckWebHandler: /RestrictedFields/{TableName}
handler40=Consultingwerk.Web2.WebHandler.GetImageNamesHandler: /ImageNames

UTF-8 based deployments available

Starting August 14th 2016 we ship our source code also as UTF-8 encoded. The ZIP files ending with _utf8.zip contain the source code encoded with that code page. The source code in the remaining archives is still encoded in ISO8859-1. Also on Github there is a new branch containing the OpenEdge 11 based source code in UTF-8.

Related article (Progress K-Base): How to get Progress Developer Studio to save in UTF-8 encoding

New Feature Documentation

Download Link

http://esd.consultingwerkcloud.com/

https://github.com/consultingwerk/SmartComponentLibrary

Overview of included tickets


Bug

SCL-2905 Fixed issue with ServiceLoader failing when RequiredDatabase is not SmartDB and required database it is not connected,

Description:

We have fixed an issue where the Service Loader was attempting to load a service instance even though the required database(s) have not been connected. The issue occurred in the case that the required database was not the SmartDB.

SCL-2906 WinKit: Resolved an issue with the TimerTick event firing multiple times when closing an EmbededWindowForm

Description:

When the WINDOW-CLOSE event of an embedded window was showing a (modal) dialog the TimerTick event might have fired multiple times.
This issue is resolved now.

SCL-2907 Fixed regression: Business Entity Designer not able to delete a temp-table

Description:

We have resolved an issue in the Business Entity Designer that disallowed deletion of tables, fields, indexes or relations from the design canvas.
The issue was caused by the new version of the diagram control used since the 2020-01-20 release.

SCL-2908 Legacy GUI Frame Migration does not show current list of controls after dragging second .w file

Description:

We have resolved an issue which caused the Legacy GUI Frame migration to not refresh the list of controls after dragging a new .w file into the window.
The issue was seen when the first frame name found in the opened file matched the frame name that was previously selected in the previously opened .w file.
The issue is now fixed.

SCL-2909 Fixed issue in Legacy browse migration issue when browse column references variable array element

Description:

We have resolved an issue in the BrowseParser class that was causing the parsing to fail when a column was referencing an array element not specified by a constant index.

New Feature

SCL-2372 Implemented a Widget Handle properties viewer

Description:

A new viewer for the properties of a handle based object has been implemented that can be used like this:

DEFINE QUERY qry FOR Customer . 

Consultingwerk.Windows.Util.Forms.WidgetHandlePropertiesForm:DisplayPropartiesOfHandle (QUERY qry:HANDLE).
Consultingwerk.Windows.Util.Forms.WidgetHandlePropertiesForm:DisplayPropartiesOfHandle (SESSION:HANDLE).


SCL-2842 Implemented functionality in GUI client and AppServer to validate each others framework version on startup

Description:

Based on a static logical property

Consultingwerk.Framework.GuiClientStartupManager:ValidateAppServerFrameworkVersion


the GUI client and AppServer now can validate each others version on client startup. When set to TRUE (default value, e.g. settable through the JSON configuration file) the Client will call into the AppServer and both tiers will compare their Framework versions.
The AppServer will write a message to the logfile when the versions do not match.
The client will display a message and prompt the user if starting the application should be continued or not.

SCL-2904 Providing version specific variants of the Consultingwerk.RadGridViewSupport assembly

Description:

As the Consultingwerk.RadGridViewSupport .NET Assembly has version specific dependencies to the Telerik RadControl assemblies, we have to provide versions of this assembly specific to the version of the RadControls in use.
Customers must reference the matching version of the Consultingwerk.RadGridViewSupport assembly in assemblies.xml