Table of Contents | ||
---|---|---|
|
Version Information
OpenEdge Release | Version Information |
---|---|
11.7.9, 11.7.10, 12.2, 12.3, 12.4 | Release 11.7 #67142@2021-08-02 |
OpenEdge 12.3 support!
We are pleased to announce that we are not aware of any issues using the SmartComponent Library on OpenEdge 12.3. We hereby declare OpenEdge 12.3 fully supported for the SmartComponent Library as of the release of November 24th 2020.
...
Progress has reported severy issues with OpenEdge GUI for .NET and .NET 4.7: GUI .Net Application crashes after .Net upgrade to 4.7
When using the .NET Framework 4.7, please make sure, you upgrade to OpenEdge 11.6.4 or OpenEdge 11.7.2 or later. Also, it may be required to recompile the application on a PC running .NET Framework 4.7 when applications are also executed on a PC with .NET Framework 4.7.
Introducing the SmartComponent Library developer forum
Got questions about using the SmartComponent Library? Wish to discuss feature requests with other users of the SmartComponent Library? To facilitate networking in the growing number of SmartComponent Library users and developers, we've added a developer forum on our new home-page. The developer forum can be found at: https://www.consultingwerk.com/support/forum
A login is required to participate in the forum. Don't be shy - create your account today!
...
Release Notes
Following the release of the OpenEdge 11.7 Release we have completed our testing of the SmartComponent Library on this release of Progress and are proud to announce formal support for the SmartComponent Library on OpenEdge 11.7 with the 2017-04-24 release of the SmartComponent Library. Generally we recommend customers on OpenEdge 11 to upgrade to OpenEdge 11.7 quickly. Starting the 2017-07-14 release we are supporting OpenEdge 11.7 Service Pack 1 (11.7.1).
...
During our tests on OpenEdge 11.7.3 we have experienced the following issues:
[SCL-2216] - 11.7.3 Visual Designer disabling properties of ABL user controls
The issue has been resolved by Progress Software with hotfix 007 for OpenEdge 11.7.3.
...
During our tests on OpenEdge 11.7.2 we have experienced two issues:
[SCL-2007] - Correct support for WebHandler in CcsServiceManager
[SCL-2008] - Closing SmartWindowForm causes crash on OpenEdge 11.7.2
We consider it mandatory for customers using OpenEdge 11.7.2 to use at least the release #44166@2017release #44166@2017-11-27 of the SmartComponent Library.
Due to an fix for
[SCL-1924] - SmartViewerControl: copy mechanism cannot cope with clob datatype
from Progress Software for in OpenEdge 11.7.2.001 we further recommend all customers to apply this hotfix as well.
...
We have updated proparse with further enhancements in this release (see https://github.com/consultingwerk/proparse/releases/tag/4.0.1.1177). Please download the .NET Assemblies ZIP file from our ESD and replace the proparse.net.dll in your environment with the latest one. The new assembly reference is:
|
As proparse is used by our Business Entity Generator, this new version of the proparse.net Assembly is also relevant for customers not doing GUI for .NET development and require support for parsing new ABL language constructs.
...
When users with no Login Company set should be able to login using the SmartHybridRealm, it's required to set the Login Company Tennant Domain (similar to the field in the Login Company Maintenance) in the .restapplicationsettings / .applicationsettings, e.g.:
|
This is required as the Hydrid Realm Interface from Progress does not provide the domain name to the authentication method.
...
This is an overview of the web handlers supported by this release
|
|
|
UTF-8 based deployments available
...
New Feature Documentation
Support for RESTful invocation of Business Task and Business Entity Methods
Invalid Proparse code-page setting corrupts temp-table field labels during "Refresh from Include"
Using Invokable Business Entity Methods with Dataset Model Classes
Searching data using ROWID's within the SmartBusinessEntityAdapter
Changes to the SmartDB and SmartDB upgrade and migration utility
How do I control the amount of details provided for error messages caused by our web handler
Download Link
http://esd.consultingwerkcloud.com/
...
Added the functionality to in addition of removing the areas, replacing the areas by command line paramater prescribed areas. When specifying -Dtablearea -Dindexarea -Dlobarea
See https://consultingwerk.atlassian.net/wiki/spaces/SCL/pages/8093744/SmartDB+Upgrade+and+Migration+Routine for more information
SCL-3417 Validate Design in the Business Entity Designer now checks for reserved ABL keywords in Temp-Table-, Field- and Index Names
...